RESEARCH PRODUCTS CORP         -- SUPER FILTER COAT 412                        
=======================================================
MSDS Safety Information 
=======================================================
FSC: 8030
MSDS Date: 11/01/1993
MSDS Num: BWPMR
LIIN: 00N057202
Product ID: SUPER FILTER COAT 412
MFN: 01
Responsible Party
Cage: 82866
Name: RESEARCH PRODUCTS CORP
Address: 1015 E WASHINGTON AVE
City: MADISON WI 53703
Info Phone Number: 608-257-8801
Emergency Phone Number: 608-257-8801
Preparer's Name: JIM ENRIGHT
Published: Y
=======================================================
Contractor Summary 
=======================================================
Cage: 82866
Name: RESEARCH PRODUCTS CORP
Address: 1015 EAST WASHINGTON AVE
City: MADISON WI 53703
Phone: 608-257-8801
=======================================================
Ingredients 
=======================================================
Cas: 7732-18-5
RTECS #: ZC0110000
Name: WATER
% Wt: 55
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Name: SOLUBLE HYDROCARBON OIL
% Wt: 44
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 9002-88-4
RTECS #: TQ3325000
Name: POLYETHYLENE
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 99-76-3
RTECS #: DH2450000
Name: BENZOIC ACID, P-HYDROXY-, METHYL ESTER; (METHYL PARABEN)
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data 
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: SWALLOWING MAY CAUSE VOMITING OR DIARRHEA.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: ASTHMATICS MAY EXPERIENCE BREATHING
  DIFFICULTIES IF EXPOSED TO SPRAY MIST.
First Aid: INHALATION: GET TO FRESH AIR. EYES: IMMEDIATELY AND THOROUGHLY FLUSH
  WITH WATER FOR AT LEAST 15 MINUTES. SKIN: THOROUGHLY WASH WITH SOAP AND
  WATER. INGESTION: DO NOT INDUCE VOMITING; CALL PHYSICIAN IM MEDIATELY.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: TREAT AS WATER SOLUBLE HYDROCARBON OIL-FLUSH WITH
  WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: HANDLE AS FEDERAL, STATE AND LOCAL CODES DICTATE FOR
  SOLUBLE OIL.
Handling And Storage Precautions: DO NOT FREEZE OR SUBJECT TO HIGH
  TEMPERATURES. STORE AT 60F-90F. DO NOT HANDLE OR STORE NEAR HEAT, SPARKS,
  FLAME, OR STRONG OXIDANTS.
Other Precautions: KEEP CONTAINERS CLOSED WHEN NOT IN USE.
=======================================================
Fire and Explosion Hazard Information 
=======================================================
Extinguishing Media: USE CLASS B EXTINGUISHER.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
  N). BURNS AS HYDROCARBON OIL IF WATER IS EVAPORATED. COOL EXPOS CNTNRS
  W/WATER SPRAY.AVOID BRTHG VAPS & FUMES.
Unusual Fire/Explosion Hazard: BURNS AS HYDROCARBON OIL IF WATER IS EVAPORATED.
=======================================================
Control Measures 
=======================================================
Respiratory Protection: NORMALLY NOT NEEDED. USE NIOSH/MSHA APPROVED AIR
  SUPPLIED RESPIRATORY PROTECTION IN CONFINED OR ENCLOSED AREAS.
Ventilation: USE IN WELL-VENTILATED AREA. PROVIDE GREATER THAN 60 FPM HOOD OR
  FACE VELOCITY FOR CONFINED SPACES.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGG & (SUPDAT)
Other Protective Equipment: USE CHEMICAL-RESISTANT APRON OR OTHER CLOTHING IF
  NEEDED TO AVOID PROLONGED SKIN CONTACT.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: EYE PROTECTION: FULL LENGTH FACESHIELD (FP N).
=======================================================
Physical/Chemical Properties 
=======================================================
B.P. Text: 212F,100C
Spec Gravity: 0.97 (H*2O=1)
Solubility in Water: COMPLETE
Appearance and Odor: OFF-WHITE EMULSION-BLAND ODOR.
=======================================================
Reactivity Data 
=======================================================
Stability Indicator: YES
Materials To Avoid: STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: SMOKE, CARBON MONOXIDE, AND SULFUR OXIDES IN
  CASE OF INCOMPLETE COMBUSTION.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information 
=======================================================
=======================================================
Ecological Information 
=======================================================
=======================================================
MSDS Transport Information 
=======================================================
=======================================================
Regulatory Information 
=======================================================
=======================================================
Other Information 
=======================================================
=======================================================
HAZCOM Label 
=======================================================
Product ID: SUPER FILTER COAT 412
Cage: 82866
Company Name: RESEARCH PRODUCTS CORP
Street: 1015 EAST WASHINGTON AVE
City: MADISON WI
Zipcode: 53703
Health Emergency Phone: 608-257-8801
Label Required IND: Y
Date Of Label Review: 02/07/1995
Status Code: C
Label Date: 02/07/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: SWALLOWING MAY CAUSE VOMITING OR DIARRHEA.
  CHRONIC: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
  information is formulated for use by elements of the Department of Defense.
  The United States of America in no manner whatsoever expressly or implied
  warrants, states, or intends said information to have any application, use or
  viability by or to any person or persons outside the Department of Defense
  nor any person or persons contracting with any instrumentality of the United
  States of America and disclaims all liability for such use. Any person
  utilizing this instruction who is not a military or civilian employee of the
  United States of America should seek competent professional advice to verify
  and assume responsibility for the suitability of this information to their
  particular situation regardless of similarity to a corresponding Department
  of Defense or other government situation.