Click here for Spanish Version OSHA HAZARD COMMUNICATION STANDARD 29 CFR 1910.1200: MATERIAL SAFETY DATA SHEETE+
|
Manufacturer | Refrigeration
Technologies 2572-C E. Fender Ave. Fullerton, CA 92831 |
Emergency Phone Numbers | (800)255-3924 [Chem-Tel] |
Product Information | (800)869-1407 |
HAZARDOUS INGREDIENTS
Hazardous Components
NONE
PHYSICAL/CHEMICAL
CHARACTERISTICS
Boiling Point - 212 F
Vapor Pressure - Not
Tested
Vapor Density - Not Tested
Solubility in Water -
100%
Appearance and Odor - Clear
Specific Gravity -
1.04
Melting Point - Not Tested
Evaporation Rate - Not
Tested
VOC Content - None
FIRE AND EXPLOSION HAZARD
DATA
Flammable Limits -
Not Tested
Extinguishing Media - None
Special Fire
Fighting Procedures - None
Unusual Fire and Explosion Hazards -
None
Stability - Stable
Conditions
to Avoid - None
Incompatible Material to Avoid - None
Hazardous
Decomposition or Byproducts - None
Hazardous Polymerization -
None
Conditions to Avoid - None
HEALTH HAZARD DATA
Routes of Entry
Inhalation? -
Possible Skin? - Possible Ingestion? - Possible.
Health Hazards -
Same as signs and symptoms of exposure.
Skin - Slight irritation
possible.
Ingestion - Nausea.
Inhalation - Not expected to be a
problem.
Medical conditions generally aggravated by exposure.
Same
as signs and symptoms of over exposure.
Emergency and First Aid Procedures.
SKIN - Wash with soap and water.
INGESTION - Drink
large amounts of water to dilute. Call physician.
INHALATION - See
above.
EYES - Flush with water, if irritation develops, seek medical
attention.
PRECAUTIONS OF
SAFE HANDLING AND USE
Steps to be
taken in case material is released or spilled - Soak up with inert,
absorbent material. Scoop up and place in a proper waste disposal
container.
Waste Disposal Method - Dispose of in accordance with
state and local regulations. Precautions to be taken in handling and
storing - store in a cool, dry place, out of direct sunlight. Do not
freeze or heat above 110°F.
Other Precautions: Keep out of reach of
children. Follow directions on the container for proper use of this
product.
CONTROL
MEASURES
Respiratory Protection -
Open all doors and windows. Exposures above the TLV or PEL require a
NIOSH approved respirator equipped for the exposure or suitable
respiratory protection per 29 CFR 1910.134.
Ventilation: Not
Required
Local Exhaust - If Available
Mechanical - If Available
Not intended for
internal consumption. Not expected to present a hazard under anticipated
conditions of use. The information in this MSDS relates only to the
product designated herein and does not relate to the use in combination,
mixture, process, or otherwise with any other material, or to the use of
this product by others which is beyond our
control.
|