A/C, Single Phase, Split Gas Furnace Single Stage, Multi Position "A" Coil H4A6S/N96VSN/EAM4X
Air Conditioner Condenser
- 80% AFUE
- Flame roll-out sensors standard
- Category I venting
- Blocked vent switch
- Louvered door
- 24 VAC and 115 VAC humidifier terminal
- Electronic air cleaner terminal
- Select sizes approved for twinning, refer to accessory kit listing
- N80ESL - Low NOx units are designed for California installations and can be installed in air quality management districts with a 40ng/J NOx emissions limit
- Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193
- Adjustable heating blower OFF delay
- Factory set blower ON delay
- RPJ aluminized steel heat exchanger
- High temperature limit control designed to prevent overheating
- Direct ignition with Silicon Nitride igniter
- One piece prepainted steel cabinet
- In-shot burners
- 33 1/3” (847mm) high, for ease of installation
- Quarter turn knobs for easy door removal and secure attachment
- Factory shipped for natural gas, convertible to propane with accessory kit
- Four position - upflow/downflow/horizontal (left/right) installation
- Three position inducer elbow capability
- Through the casing flue pipe for counterflow applications
- Common venting with other Category I appliances
- Masonry chimney adapter available
- Self diagnostics
- Slide out blower assembly
Gas Furnace
- Fully insulated steel cabinet
- Dehumidification feature in cooling
- Certified to leak 2% or less of nominal air conditioning CFM delivered (when pressured to 1 inch water column with all present air inlets, air outlets, and condensate drain port(s) sealed
- VCT Constant Torque Variable Speed Motor
- Supports Single & Two Stage A/C
- Aluminized steel RPJ primary heat exchanger
- Stainless Steel Secondary Heat Exchanger
- Direct ignition with Silicon Nitride ignitor
- Direct vent (2-pipe), single-pipe venting, or ventilated combustion air
- 35” (889mm) high, for ease of installation
- Four position - upflow/downflow/horizontal (left/right) installation
- At least twelve different venting configurations
- Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately)
- Self diagnostics with super bright LED
- Concentric vent available
- Twining capable (select sizes) w/ kit
Evaporator Coil
- Corrosion resistant aluminum tube
- Bolt-on TXV metering device factory installed on all models (equalizer tube brazed in)
- TXV and manifold positioned to the side for easier cleaning
- Innovative drain pan design for complete water removal
- Two condensate drain connections (Additional two for horizontal installation)
- 2-piece delta plate for easier removal and cleaning
- Cabinet widths match flush with Arcoaire gas furnaces
- Hemmed flanges for safer handling
- Foil faced insulation
- Non-sweat cabinet, even at extreme conditions
- Cabinets meet or exceed 2% air leakage codes
- Sturdy, 22 gauge, pre-painted steel cabinet
- One or two UV light knock-outs provided on cabinet (depending on size)