Catalog pricing shown. Please log in to see your pricing.

TVS040M8/H8HT4BA

TVS040M8/H8HT4BA
Call To Order
Condensing unit, air cooled, single semi-hermetic compressor, medium/high temp, R404A, R507, R407C, R22, 40 HP, 460/3/60
URI Part Number:
TVS040M8/H8HT4BA
Vendor Name:
Trenton Refrigeration Products
Length (In.):
222 3/8
Width (In.):
44 3/4
Compressor:
6DJ3A400EFSD
Compressor New:
6DJNR40METSN
Connection Liquid (In.):
1 1/8 / 1 3/8
Connection Suction (In.):
2 1/8
Connection Type:
ODS
Height (In.):
55
Horsepower:
40
Maximum Fuse / Breaker Size (Amps):
150 / 175
MCA (Amps):
98.6 / 108.4
Oil:
Polyol Ester
Oil_short:
POE
Receiver Capacity 90 % Full (Lbs.):
189
Refrigerant:
R404A, R507, R407C, R22
Sort:
17.0
Voltage:
460/3/60
Shipping Weight (Lbs.):
3165
  • Units are cULus Listed
  • Designed for use with R22, R404A and R507
  • Energy efficient compressors with POE or mineral oil. Several Options to choose from: Copeland Discus, Bitzer reciprocating, Carlyle reciprocating, Copeland screw
  • Thermospan condenser™ core design eliminates tube sheet leaks and provides reliable operation
  • 3/8" condenser tubes reduces refrigerant charge
  • Generously sized condenser allows unit to operate at higher than normal ambient conditions Optional coating and fin surfaces for condenser core protection available
  • Specially designed, thermally protected and permanently lubricated ball bearing condenser fan motor(s)
  • Receivers are liberally sized and include inlet as well as outlet service valves
  • Utilizes pre-formed internal piping, eliminates welded joints and reduces chances of a leak
  • End compartment panels allow unrestricted access to service the compressor(s) and all other components
  • Raceway for pressure control wiring and connections provides neat appearance
  • Units are environmently friendly operating on less power and refrigerant charge

Standard Features

  • Spring mount compressor with discharge vibration eliminator
  • Compressor crankcase heater
  • Condenser fan cycling control (pressure) on two-fan models and up
  • Fused condenser fan motors
  • Part-winding start on all 30 HP and up, operating on 208/230V-3Ph.
  • Compressor head cooling fans on low temperature models
  • Flexible hose on all compressor pressure control connections
  • Receiver inlet/outlet valves and safety pressure relief valve
  • Replaceable liquid line drier & sight glass
  • Anti-short cycle time delay relay
  • Oil failure control (non-electronic)
  • Discharge line thermostat
  • Separate HP and LP compressor controls
  • Lock out relay, SPDT alarm circuit
  • Two valve adjustable (pre-set at factory) low ambient head pressure control


  • Receiver capacity for R404A
Specification Sheet

Installation Instructions