PACKAGE COMMERCIAL 12.5 TON, TWO STAGE, DUEL CIRUIT, CONVERTIBLE AIR CONDITIONING UNIT WITH LOW GAS HEAT, MEDIUM STATIC BLOWER WITH VFD , 208-230/3/60, R410A
WARNING: This product can expose you to chemicals including Lead, and Lead, compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
One piece, high efficiency gas heating, electric cooling with a low profile, prewired, tested, and charged
Full perimeter base rail with built-in rigging adapters and fork truck slots
Pre painted exterior panels and primer coated interior panels tested to 500 hours salt spray protection
Fully insulated cabinet
All units are convertible from downflow to horizontal airflow; no special adapter curbs are necessary
Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving fan motor delay
High efficiency gas heat with induced draft flue exhaust design
All units have high and low pressure switches
Two inch disposable fiberglass type return air filters in dedicated rack with tool-less filter access door
Refrigerant circuits contain a liquid line filter drier to trap dirt and moisture
Exclusive non corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design
Belt drive evaporator fan motor and pulley combinations available to meet most applications
Access panels with easy grip handles provide quick and easy access to the blower and blower motor, control box, and compressors.
No strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal.
Newly designed terminal board facilitates simple safety circuit troubleshooting and simplified control box arrangement
Redundant gas valve, up to two stages of heating
Capable of thru-the-base or thru-the curb gas line routing
Outdoor temperature cooling operation range up to 115°F (46°C) and down to 30°F (-1°C ) [25°F for 6 to 12 1/2 ton units] using accessory winter start kit
Fixed orifice metering devices on all models to precisely control refrigerant flow
Large, laminated control wiring and power wiring drawings are affixed to unit to make troubleshooting easy
Single point gas and electrical connections
Two stage cooling on all models
Two scroll compressors with internal line break overload protection
Outdoor coils constructed of aluminum fin and aluminum tube microchannel design.