Log in for pricing and inventory.

FAS120HAAA2A0A

FAS120HAAA2A0A
Commercial air handler, Air Conditioning, 10 tons, 208-230/3/60 volt, 2-speed indoor fan motor controller (VFD)
Engineered Items :
Yes
LTL Only :
Yes
Direct-Expansion Coil Face Area (Sq Ft) :
10.01
Voltage :
208-230
Branch Pickup Only :
No
Sound Rating Decibels :
91.6
Refrigerant :
R454B
Phase :
3
LogoImage :
L/Logo_ArcoAire.jpg
manufacturerName :
Arcoaire
longDescription :
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint available
  • High static design meets a wider range of applications than competitive packaged air handler lines
  • Multiposition design can be installed horizontally or vertically without modification (two sloped drain pans)
  • Cooling coils with mechanically bonded fins that provide peak heat transfer
  • Accessory electric heat kits available from 5 - 70 kW
  • Hot water and steam coils optionally available
  • Economizer accessory optionally available
  • Factory installed TXV
  • Single refrigerant circuit on 072 and 091 sizes. Dual refrigerant circuit on 120-300
    Dual circuit can be field modified for use on single circuit condensers.
  • The 2" (51 mm) factory installed disposable filters remove dust and airborne particles from the occupied space to serviceable components
  • Easy installation and maintenance; removal of one side panel allows access to serviceable components
  • Cleanable thermal insulation contains an immobilized anti-microbial agent to inhibit the growth of bacteria and fungi
  • Single blower on 6 to 10 ton units; dual blower on 12.5 to 25 ton units.
  • 8th position of part number:
    A = Standard Static Standard Efficiency Motor / Standard Drive
    B = High Static Standard Efficiency Motor / High Drive
    D = Standard Static High Efficiency Motor / Standard Drive
    E = High Static High Efficiency Motor / High Drive
Fans Nominal Airflow (CFM) :
4,000
Vendor Name:
Arcoaire
Nominal Tons_Sort :
10.0
SKU :
FAS120HAAA2A0A
Maximum Fuse / Breaker Size (Amps) :
15
Nominal Tons :
10
Operating Weight (Lbs.) :
425
Specials :
No
Web Description :
Commercial air handler, Air Conditioning, 10 tons, 208-230/3/60 volt, 2-speed indoor fan motor controller (VFD)
Number of Circuits :
2
Fans Airflow Range (CFM) :
3000-5000
manufacturerSKU :
FAS120HAAA2A0A
Specials Description :
Commercial air handler, A/C, 10 tons, 208-230/3/60, 2-speed indoor fan motor controller (VFD)
Sort :
2.5
Weight :
425.0 lb
Hertz :
60
URI Part Number:
FAS120HAAA2A0A
Vendor Part Number:
FAS120HAAA2A0A
Length (In.):
28 3/16
Width (In.):
49
Height (In.):
56 1/16
Connection Liquid (In.):
5/8
Connection Suction (In.):
1 1/8
Fans Nominal Motor Horsepower:
2.4
MCA (Amps):
9.0
Shipping Weight (Lbs):
425.00
Prop65:
WARNING: This product can expose you to chemicals including Lead and Lead compounds, which are known to the State of California to cause cancer and developmental harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
425.00
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint available
  • High static design meets a wider range of applications than competitive packaged air handler lines
  • Multiposition design can be installed horizontally or vertically without modification (two sloped drain pans)
  • Cooling coils with mechanically bonded fins that provide peak heat transfer
  • Accessory electric heat kits available from 5 - 70 kW
  • Hot water and steam coils optionally available
  • Economizer accessory optionally available
  • Factory installed TXV
  • Single refrigerant circuit on 072 and 091 sizes. Dual refrigerant circuit on 120-300
    Dual circuit can be field modified for use on single circuit condensers.
  • The 2" (51 mm) factory installed disposable filters remove dust and airborne particles from the occupied space to serviceable components
  • Easy installation and maintenance; removal of one side panel allows access to serviceable components
  • Cleanable thermal insulation contains an immobilized anti-microbial agent to inhibit the growth of bacteria and fungi
  • Single blower on 6 to 10 ton units; dual blower on 12.5 to 25 ton units.
  • 8th position of part number:
    A = Standard Static Standard Efficiency Motor / Standard Drive
    B = High Static Standard Efficiency Motor / High Drive
    D = Standard Static High Efficiency Motor / Standard Drive
    E = High Static High Efficiency Motor / High Drive
Documents