A/C, Single Phase, Split Gas Furnace Multi Stage, Vertical Power "V" H4A7T/N96VSN/EVD4X
Air Conditioner Condenser
- 2 Stage Copeland Scroll Ultratech Compressor
- Welded Aluminum Tube / Aluminum Fin Coil
- Improved Efficiency w/ Multi Directional Internal Enhancements
- Less Sensitivity to Pressure Drop
- Heat Shrink Wrap Protects Copper / Aluminum Joints
- AL/AL w/ Zinc Cladding Provides Enhanced Corrosion Protection
- Approximately 50% Lighter than Copper Coils
- Filter Drier Supplied for Field Installation
- Self Configuring Operation & Text Based Diagnostics w/ Ion Control
- Compressor Sound Blanket & Isolation Grommets Factory Installed
- Extended Service Valve to Accommodate Press Fittings
- High & Low Pressure Switches
- Outdoor Temp Sensor Factory Installed
- Factory Charged w/ R410A Refrigerant
- Long Line Set Capability (refer to spec sheet for details)
- Low Ambient Cooling Capable w/ Optional Kit
- Galvanized Steel Cabinet w/ High Gloss, Baked on Powder Coat Paint
- Corner Posts for Added Cabinet Strength
- Coated Hail Guard Coil Protection
- Post Painted (black) Coil
- Coated Cabinet Screws
- Internal Pressure Relief Valve & Thermal Overload
Gas Furnace
- Fully insulated steel cabinet
- Dehumidification feature in cooling
- Certified to leak 2% or less of nominal air conditioning CFM delivered (when pressured to 1 inch water column with all present air inlets, air outlets, and condensate drain port(s) sealed
- VCT Constant Torque Variable Speed Motor
- Supports Single & Two Stage A/C
- Aluminized steel RPJ primary heat exchanger
- Stainless Steel Secondary Heat Exchanger
- Direct ignition with Silicon Nitride ignitor
- Direct vent (2-pipe), single-pipe venting, or ventilated combustion air
- 35” (889mm) high, for ease of installation
- Four position - upflow/downflow/horizontal (left/right) installation
- At least twelve different venting configurations
- Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately)
- Self diagnostics with super bright LED
- Concentric vent available
- Twining capable (select sizes) w/ kit
Evaporator Coil
- Corrosion Resistant Aluminum
- Low Pressure Drop
- TXV metering device factory installed
- Compact design, shorter than A-coils
- Hemmed flanges for safer handling
- Cabinets meet or exceed 2% air leakage codes
- UV knockout
- No delta plate allows easy cleaning
- 30-40% Lighter than “A” Coils
- 80% Fewer Factory Braze Joints vs. “N” Coils
- V Design Reduces Cabinet Sweating
- Helium leak tested @ the factory