Log in for pricing and inventory.

TZA13NY48AJ1NA

TZA13NY48AJ1NA
Thermal Zone Air Conditioner 13 Seer 4.0 Ton 1 Phase 208-230V (North Doe Region Only) - R454B
LTL Only :
Yes
Voltage :
208-230
Branch Pickup Only :
No
Vendor Name:
Thermal Zone
longDescription :
  • Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards, weather corrosion
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliabilty
  • Easily Accessible Control Box: Ease of installation and serviceability
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems.
  • Refrigerant Detection System: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
manufacturerName :
Thermal Zone
Sound Rating Decibels :
71
Motor Horsepower :
1/5
Refrigerant :
R454B
manufacturerSKU :
TZA13NY48AJ1NA
SKU :
TZA13NY48AJ1NA
Weight :
200.0 lb
CFM :
4264
LogoImage :
L/Logo_ThermalZone.jpg
Web Description :
Thermal Zone Air Conditioner 13 Seer 4.0 Ton 1 Phase 208-230V (North Doe Region Only) - R454B
Specials :
No
Phase :
1
Sort :
6.0
Cooling Capacity (BTUH) :
48000
Nominal Tons :
4
Hertz :
60
URI Part Number:
TZA13NY48AJ1NA
Vendor Part Number:
TZA13NY48AJ1NA
Depth (In.):
33.75
Width (In.):
33.75
Height (In.):
39.00
Connection Liquid (In.):
3/8
Connection Suction (In.):
7/8
Shipping Weight (Lbs):
200.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Cooling Efficiency (SEER2):
13.4
Weight (Lbs):
200.00
  • Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards, weather corrosion
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliabilty
  • Easily Accessible Control Box: Ease of installation and serviceability
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems.
  • Refrigerant Detection System: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
Documents