Log in for pricing and inventory.

TZPLS15422AA

TZPLS15422AA
Condensing unit, Heat Pump, 3.5 tons, R410A, 208-230/1/60
Engineered Items :
Yes
LTL Only :
Yes
Maximum Fuse / Breaker Size (Amps) :
40
Branch Pickup Only :
No
Voltage :
208-240/1
Vendor Name:
Thermal Zone
Nominal Tons_Sort :
3.5
manufacturerName :
Thermal Zone
SKU :
TZPLS15422AA
CFM :
1350
Cooling Efficiency (SEER) :
15.0
longDescription :
  • New composite base pan – dampens sound, eliminates corrosion and reduces number of fasteners needed
  • Improved tubing design – reduces vibration and stress, making unit quieter and reducing opportunity for leaks
  • Optimized defrost characteristics - decrease defrosting and provide better home comfort
  • Powder coat paint finish – for a long lasting professional finish
  • Optimized reversing valve sizing – improves shifting performance for quieter unit operation and increased life of the system
  • Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
  • Copeland scroll compressor – uses 70% fewer moving parts for higher efficiency and increased reliability
  • Modern cabinet aesthetics – increased curb appeal with visually appealing design
  • Vertical louvre panels – provide ultimate coil protection, enhances cabinet strength, and increases cabinet rigidity
  • Optimized fan orifice – optimizes airflow and reduces unit sound
  • Rust resistant screws – confirmed through 1500-hour salt spray testing
  • 3" between valves, 4" below valves, 5" above valves – provides a minimum working area of 27-square inches for easier access
  • Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into the base
  • 15" wide, industry leading corner service access – makes repairs easier and faster
  • External gauge port access – allows easy connection of “low-loss” gauge ports
  • Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain "out of the box" performance
  • Fewer cabinet fasteners – allow for faster access to internal components and hassle-free panel removal
  • Service trays – hold fasteners or caps during service calls
  • QR code – provides technical information on demand for faster service calls
  • Fan motor harness with extra-long wires – allows unit top to be removed without disconnecting fan wire
Web Description :
Condensing unit, Heat Pump, 3.5 tons, R410A, 208-230/1/60
LogoImage :
L/Logo_ThermalZone.jpg
Cooling Capacity (BTUH) :
42500
Cooling Efficiency (EER) :
12.5
Specials :
No
Refrigerant :
R410A
Specials Description :
Condensing unit, Heat Pump, 3.5 tons, R410A, 208-230/1/60
Rating Selection :
TZHSLTST4821
Nominal Tons :
3.5
Sort :
4.0
manufacturerSKU :
TZPLS15422AA
Weight :
228.0 lb
URI Part Number:
TZPLS15422AA
Vendor Part Number:
TZPLS15422AA
Length (In.):
37.64
Width (In.):
37.56
Height (In.):
38.35
Connection Liquid (In.):
3/8
Connection Suction (In.):
7/8
MCA (Amps):
24
Shipping Weight (Lbs):
228.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
228.00
  • New composite base pan – dampens sound, eliminates corrosion and reduces number of fasteners needed
  • Improved tubing design – reduces vibration and stress, making unit quieter and reducing opportunity for leaks
  • Optimized defrost characteristics - decrease defrosting and provide better home comfort
  • Powder coat paint finish – for a long lasting professional finish
  • Optimized reversing valve sizing – improves shifting performance for quieter unit operation and increased life of the system
  • Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
  • Copeland scroll compressor – uses 70% fewer moving parts for higher efficiency and increased reliability
  • Modern cabinet aesthetics – increased curb appeal with visually appealing design
  • Vertical louvre panels – provide ultimate coil protection, enhances cabinet strength, and increases cabinet rigidity
  • Optimized fan orifice – optimizes airflow and reduces unit sound
  • Rust resistant screws – confirmed through 1500-hour salt spray testing
  • 3" between valves, 4" below valves, 5" above valves – provides a minimum working area of 27-square inches for easier access
  • Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into the base
  • 15" wide, industry leading corner service access – makes repairs easier and faster
  • External gauge port access – allows easy connection of “low-loss” gauge ports
  • Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain "out of the box" performance
  • Fewer cabinet fasteners – allow for faster access to internal components and hassle-free panel removal
  • Service trays – hold fasteners or caps during service calls
  • QR code – provides technical information on demand for faster service calls
  • Fan motor harness with extra-long wires – allows unit top to be removed without disconnecting fan wire
Documents