Log in for pricing and inventory.

2FES32DU0A

2FES32DU0A
Compressor, semi-hermetic, air or refrigerant cooled, 3 HP, Alkylbenzene oil, 208-230/3/60
Application by Refrigerant :
High Temp - R22, Medium Temp - R22, Low Temp - R22
Rated Load Amps :
11.8
Alternate Number :
2C0407SH-2DU-A
LTL Only :
Yes
manufacturerSKU :
2FES-3-2DU-0A
Specials Description :
Compressor, semi-hermetic, air or refrigerant cooled, 3 HP, Alkylbenzene oil, 208-230/3/60
Branch Pickup Only :
No
Sort :
9.0
Number of Cylinders :
2
manufacturerName :
Bitzer
LogoImage :
L/Logo_bitzer.jpg
Web Description :
Compressor, semi-hermetic, air or refrigerant cooled, 3 HP, Alkylbenzene oil, 208-230/3/60
Vendor Name:
Bitzer
Web Search :
Volt
Application :
High Temp, Medium Temp, Low Temp
Oil :
Alkylbenzene
Displacement (CFH) :
407
Weight :
104.0 lb
Specials :
No
longDescription :

C1 to C8 Series

  • One compressor version for R134a, R404A, R448A, R449A, R502, R507A, R407C, R22 refrigerants (with oil change)
  • Wide application range
  • High cooling capacity and minimal energy requirements through efficient valves, minimal dead space, efficient large volume motor
  • Quiet, minimal vibration through optimised mass balance, integrated pulsation mufflers (C2 to B6 series)
  • Solid valve plate design
  • Thermal motor monitoring PTC sensors

C1 to C4 Octagons

  • PTFE coated bearings
  • Extremely low height
  • Shut off valves within compressor contour (C1 to C3)
  • Easy switching from suction gas cooling to air cooling at the same connection (C1 to C3)
SKU :
2FES32DU0A
Refrigerant :
R22
Horsepower :
3
Voltage :
208-240/3
Oil_short :
AB
URI Part Number:
2FES32DU0A
Vendor Part Number:
2FES-3-2DU-0A
Length (In.):
14.00
Width (In.):
12.00
Height (In.):
14.00
Connection Discharge (In.):
1/2
Connection Suction (In.):
5/8
Mount (In.):
6.38 x 8.19
Shipping Weight (Lbs):
104.00
Weight (Lbs):
104.00

C1 to C8 Series

  • One compressor version for R134a, R404A, R448A, R449A, R502, R507A, R407C, R22 refrigerants (with oil change)
  • Wide application range
  • High cooling capacity and minimal energy requirements through efficient valves, minimal dead space, efficient large volume motor
  • Quiet, minimal vibration through optimised mass balance, integrated pulsation mufflers (C2 to B6 series)
  • Solid valve plate design
  • Thermal motor monitoring PTC sensors

C1 to C4 Octagons

  • PTFE coated bearings
  • Extremely low height
  • Shut off valves within compressor contour (C1 to C3)
  • Easy switching from suction gas cooling to air cooling at the same connection (C1 to C3)
Substitutes Documents