Catalog pricing shown. Please Sign In to see your pricing.

BG1600M02CR1AD

BG1600M02CR1AD
Intermittent pilot ignition module, continuous retry: 60 minutes
Please note an alternative model exists for this Part Number. Please see the Supersedes tab.
Vendor Name:
Baso
URI Part Number:
BG1600M02CR1AD
Vendor Part Number:
BG1600M02CR1AD
Shipping Weight (Lbs.):
1
Continuous Retry:
60 Minutes
Replaces:
G776RGD14C
Voltage:
24 Vac/ 50/60 Hz

BASO has designed in timings on various Intermittent pilot controls with flame rectification to replace many Johnson Controls, Honeywell, United Technologies, Fenwal, and Robertshaw.
These are microprocessor based controls suited for direct replacement and new applications. Intermittent pilot modules provide ignition sequence, flame monitoring, and safety shutoff for boilers, furnaces, and a variety of other commercial cooking equipment. Intermittent pilot units are available with damper connection or without.
Intermittent pilot modules are available with various specifications as follows:

  • Single rod (local sense) or dual rod (remote sense) flame sensing
  • Trial for ignition 1 or 3
  • 100% shutoff/lockout with none, 5 or 60 minutes continuous retry
  • Trial times of infinite, 4, 5, 8, 10, 15, 20, 25, 30, 50, 60, 85, 90 and 120 seconds.
  • Pre-purge period of none, 4, 8, 10, 15, 30, 45, 60 seconds or 4 minutes
  • Main burner 400,000 Btu/hr max.
  • Pilot burners with flow rates of 1,500 Btu/hr or less
  • Temperature ranges of -40°F to 170°F
    Other models available upon request
Substitutes Supersedes Documents

Related Products