A70HA1

A70HA1
Temperature control, freezestat, alarm, 15 to 55°F, manual reset, 20' capillary, open low main switch, close low aux. switch, 8 (main) 3 (aux.) Amps 240 V
Web Description :
Temperature control, freezestat, alarm, 15 to 55°F, manual reset, 20' capillary, open low main switch, close low aux. switch, 8 (main) 3 (aux.) Amps 240 V
Branch Pickup Only :
No
longDescription :

The A70G, A70H, and A70K have a four-wire, two circuit contact block that contains two isolated sets of contacts.
The contacts are designed so that when the main contact opens, the auxiliary contact closes.
Typical applications would include energizing an indicator light upon low temperature cutout on a ventilating system.
Use as freezestat.
A70GA1/A70HA1 only
Low cutout stop is set and sealed at 35°F (1.6°C). Control responds only to the lowest temperature along any 1' of entire 20' element or bellows cup

manufacturerSKU :
A70HA-1C
LogoImage :
L/Logo_JohnsonControls.jpg
SKU :
A70HA1
Differential :
Manual Reset
Note 1 :
Low cutout stop is set and sealed at 35°F (1.6°C). Control responds only to the lowest temperature along any 1' of entire 20' element or bellows cup.
Bulb (In.) :
1/8 O.D. Tubing
Specials :
No
Weight :
2.18 lb
Specials Description :
Temperature control, freezestat, alarm, 15 to 55°F, manual reset, 20' capillary, open low main switch, close low aux. switch, 8 (main) 3 (aux.) FLA 240 V
manufacturerName :
Johnson Controls
Sort :
2.0
Vendor Name:
Johnson Controls
URI Part Number:
A70HA1
Vendor Part Number:
A70HA-1C
Length (In.):
8.30
Width (In.):
6.30
Height (In.):
2.70
Auxiliary Switch:
Close Low
Capillary Length:
20'
FLA Auxiliary:
3
FLA Main:
8
Switch Main:
Open Low
Shipping Height (In.):
2.5
Shipping Length (In.):
8.125
Shipping Width (In.):
6.25
Shipping Weight (Lbs):
2.18
Prop65:
WARNING: This product contains chemicals known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
2.18

The A70G, A70H, and A70K have a four-wire, two circuit contact block that contains two isolated sets of contacts.
The contacts are designed so that when the main contact opens, the auxiliary contact closes.
Typical applications would include energizing an indicator light upon low temperature cutout on a ventilating system.
Use as freezestat.
A70GA1/A70HA1 only
Low cutout stop is set and sealed at 35°F (1.6°C). Control responds only to the lowest temperature along any 1' of entire 20' element or bellows cup