Log in for pricing and inventory.

CVDT1800

CVDT1800
MAWOC CONDENSING UNIT QUIETCUBE NXT 208-230V
Please note an alternative model exists for this Part Number. Please see the Supersedes tab.
Regional Item :
001,002,003,004,005,006,007,008,010,011,012,014,015,016,017,020,021,022,025,026,028,030,031,032,033,034,035,036,037,038,039,040,041,042,044,045,046,047,048,049,051,052,053,054,055,057,058,059,0B7,0B8,0F2,0F3,0F4,0F5,0G1,0G6,0G8,0G9,0H1,0R2,0R7,0R8,0R9,0U1,0U3,0V0,0V1,0V2,0V3,0V4,0V5,0V7,0V8,0V9,0W0,0W1,0X3,0Y2,0Y3,0Y4,0Y5,0Y6,0Y7,0Y8,0Y9,402,411,419,435,446,449,450,452,453,454,455,456,458,464,468,469,471,472,473,474,475,476,477,478,479,480,481,482,484,485,489,494,495,504,560,562,565,566,568
Maximum Fuse / Breaker Size (Amps) :
40
Voltage :
208-230
Branch Pickup Only :
No
Specials :
No
manufacturerName :
Manitowoc
manufacturerSKU :
CVDT1800-261
Use with :
IDT1830C, IYT1830C
longDescription :

CVD (Cool Vapor Defrost) technology is basically a different type of ice harvest system that allows Manitowoc to move the compressor out of the customer environment. Standard remote condenser ice machines all use compressor hot gas systems to heat the evaporator during their ice harvest cycles. To make hot gas systems work, the compressor must be as physically close to the ice making evaporator as possible. This also means the noise from the compressor is always concentrated at the ice making part of the system.
Manitowoc CVD ice machines use vapor refrigerant from the receiver tank to harvest the ice. CVD systems all use large capacity refrigerant accumulators for maximum compressor protection under any operating condition.

LogoImage :
L/Logo_Manitowoc_new.jpg
Web Description :
MAWOC CONDENSING UNIT QUIETCUBE NXT 208-230V
Vendor Name:
Manitowoc
Weight :
195.0 lb
SKU :
CVDT1800
URI Part Number:
CVDT1800
Vendor Part Number:
CVDT1800-261
Depth (In.):
24.13
Width (In.):
34.00
Height (In.):
25.75
MCA (Amps):
25
Shipping Weight (Lbs):
195.00
Weight (Lbs):
195.00

CVD (Cool Vapor Defrost) technology is basically a different type of ice harvest system that allows Manitowoc to move the compressor out of the customer environment. Standard remote condenser ice machines all use compressor hot gas systems to heat the evaporator during their ice harvest cycles. To make hot gas systems work, the compressor must be as physically close to the ice making evaporator as possible. This also means the noise from the compressor is always concentrated at the ice making part of the system.
Manitowoc CVD ice machines use vapor refrigerant from the receiver tank to harvest the ice. CVD systems all use large capacity refrigerant accumulators for maximum compressor protection under any operating condition.

Supersedes