Liquid receiver, upright, 358 lbs pumpdown, inlet 2-5/8" IDS, outlet 2-1/8" IDS, 60"H
Engineered Items :
Yes
LTL Only :
Yes
Sort :
13.0
Branch Pickup Only :
No
Working Pressure Shell Side (psi) :
450
longDescription :

Designed for long, trouble-free service in even the most demanding applications.
Each standard stock receiver conforms to UL, CSA or ASME requirements for 450 psi maximum working pressure. Models with an internal diameter under 6" are UL Listed; all larger models are made according to ASME code and tagged appropriately.
All pumpdowns are calculated at 80% capacity, R22 liquid.



  • Due to the high working pressures of R410A. any receiver must be customized to conform to ASME construction. Please contact branch/customer service for more information
  • Working pressure: 450 psi
    Pumpdowns are calculated at 80% of receiver volume, R22
    For other refrigerants multiply listed value by factor below
    R12 x 1.10
    R134a x 1.01
    R404A x 0.89
    R507 x 0.88
manufacturerName :
Standard Refrigeration Company
Vendor Name:
Standard Refrigeration Company
Web Description :
Liquid receiver, upright, 358 lbs pumpdown, inlet 2-5/8" IDS, outlet 2-1/8" IDS, 60"H
LogoImage :
L/Logo_StandardRefrigeration.jpg
Specials Description :
Liquid receiver, upright, 358 lbs pumpdown, inlet 2 5/8" IDS, outlet 2 1/8" IDS, 60"H
SKU :
UR351
Specials :
No
Weight :
300.0 lb
manufacturerSKU :
UR351
Connection Type :
IDS
URI Part Number:
UR351
Vendor Part Number:
UR351
Length (In.):
18.00
Width (In.):
16.00
Height (In.):
60.00
Connection Size Inlet (In.):
2 5/8
Connection Size Outlet (In.):
2 1/8
Country of Origin:
USA
Shipping Weight (Lbs):
300.00
Weight (Lbs):
300.00

Designed for long, trouble-free service in even the most demanding applications.
Each standard stock receiver conforms to UL, CSA or ASME requirements for 450 psi maximum working pressure. Models with an internal diameter under 6" are UL Listed; all larger models are made according to ASME code and tagged appropriately.
All pumpdowns are calculated at 80% capacity, R22 liquid.



  • Due to the high working pressures of R410A. any receiver must be customized to conform to ASME construction. Please contact branch/customer service for more information
  • Working pressure: 450 psi
    Pumpdowns are calculated at 80% of receiver volume, R22
    For other refrigerants multiply listed value by factor below
    R12 x 1.10
    R134a x 1.01
    R404A x 0.89
    R507 x 0.88