Log in for pricing and inventory.

3840

3840
Suction accumulator, horizontal, 3-1/8" ID, 62 lbs holding capacity R404A
manufacturerSKU :
3840
Web Description :
Suction accumulator, horizontal, 3-1/8" ID, 62 lbs holding capacity R404A
LogoImage :
L/Logo_RefrigerationResearch.jpg
Branch Pickup Only :
No
Sort :
12.0
Specials :
No
Note 1 :
Horizontal
Connection Type :
OD
SKU :
3840
Specials Description :
Suction accumulator, horizontal, 3 1/8" ID, 62 lbs holding capacity R404A
manufacturerName :
Refrigeration Research
Orientation :
Horizontal
Weight :
58.7 lb
Vendor Name:
Refrigeration Research
longDescription :

Applications requiring intermittent operation of the refrigeration compressor may trap or hold quantities of liquid in the suction line which are suddenly dumped into the compressor as it starts up. Proper installation of the suction accumulator, just before the compressor, eliminates damage. Liquid is temporarily held in the suction accumulator and metered back to the compressor along with any oil, at a controlled rate, through the metering orifice.

  • VERTICAL models 6" diamater and smaller (also ASME 3648) rated for R410A
  • All Refrigeration Research suction accumulators of 4" through 6" diameter have fusible plugs included and installed to comply with latest UL and cUL requirements
  • All models are listed or meet code
  • Holding capacity and recommended tonnage: R404A, -20°F evaporator
  • Minimum recommended tonnage based on oil return through accumulator.
  • 3826, 3836, 3839, 3840, 3841 accumulators are horizontal orientation
URI Part Number:
3840
Vendor Part Number:
3840
Length (In.):
24.00
Connection Size (In.):
3 1/8
Diameter (In.):
10.80
Suggested Tonnage:
9.3 to 40
Shipping Weight (Lbs):
58.70
Weight (Lbs):
58.70

Applications requiring intermittent operation of the refrigeration compressor may trap or hold quantities of liquid in the suction line which are suddenly dumped into the compressor as it starts up. Proper installation of the suction accumulator, just before the compressor, eliminates damage. Liquid is temporarily held in the suction accumulator and metered back to the compressor along with any oil, at a controlled rate, through the metering orifice.

  • VERTICAL models 6" diamater and smaller (also ASME 3648) rated for R410A
  • All Refrigeration Research suction accumulators of 4" through 6" diameter have fusible plugs included and installed to comply with latest UL and cUL requirements
  • All models are listed or meet code
  • Holding capacity and recommended tonnage: R404A, -20°F evaporator
  • Minimum recommended tonnage based on oil return through accumulator.
  • 3826, 3836, 3839, 3840, 3841 accumulators are horizontal orientation