SORIT12

SORIT12
Pressure regulator, evaporator, solenoid stop, 1-1/8" ODF, 0 to 100 psi, 2.52 tons, 8.50" L
Pressure Range (psi) :
0 to 100
Capacity (Tons) :
2.52
Branch Pickup Only :
No
Connection Type :
ODF
Vendor Name:
Sporlan
Weight :
5.54 lb
Web Description :
Pressure regulator, evaporator, solenoid stop, 1-1/8" ODF, 0 to 100 psi, 2.52 tons, 8.50" L
Sort :
1.0
manufacturerSKU :
901611
longDescription :

This control is a nonelectric regulator which uses high-side system pressure as a source of operating power for evaporator pressure regulation.The use of highside pressure, regulated by a pilot valve, allows operation of the primary port at previously unnattainable low pressure drops. These low pressure differentials are directly related to energy savings. The pilot automatic regulator allows convenient adjustability of the evaporator pressure.

  • Opens on rise of inlet pressure
  • Use the S ORIT solenoid stop feature for hot gas defrost applications to allow full open operation after defrost for fast pulldown
  • Capacities based on 60° saturated liquid, 0°F superheat at evaporator, 25°F superheated return gas, R404A, 0°F evaporator temperature, 2 psi ?P
  • Pressure range: 0-100 psi
(S)ORIT-12, -15 and -20 Features
- High side pilot for improved temperature control and low ΔP operation
- Adjustable
- Optional solenoid "stop" feature to close valve during defrost
- Normally open design allows system evacuation without manual operator
- These EPRs are pilot operated using "high side" pressure and require a pilot supply connection from the compressor discharge to operate. They are designed to be "normally open" providing an unparalleled ability to operate with virtually no suction line pressure drop. The pilot operated design does not require the "allowable evaporator pressure change" necessary with the direct acting models, and can be simply sized based on design evaporator temperature and available pressure drop across the valve at full load conditions.
manufacturerName :
Sporlan
Specials :
No
Specials Description :
Evaporator, solenoid stop, 1 1/8" ODF, 0 to 100 psi, 2.52 tons, 8.50" L
SKU :
SORIT12
LogoImage :
L/Logo_Sporlan.jpg
URI Part Number:
SORIT12
Vendor Part Number:
901611
Length (In.):
14.75
Width (In.):
12.80
Height (In.):
5.50
Connection Size (In.):
1 1/8
Overall Height (In.):
7.22
Overall Length (In.):
8.50
Shipping Weight (Lbs):
5.54
Prop65:
WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
5.60

This control is a nonelectric regulator which uses high-side system pressure as a source of operating power for evaporator pressure regulation.The use of highside pressure, regulated by a pilot valve, allows operation of the primary port at previously unnattainable low pressure drops. These low pressure differentials are directly related to energy savings. The pilot automatic regulator allows convenient adjustability of the evaporator pressure.

  • Opens on rise of inlet pressure
  • Use the S ORIT solenoid stop feature for hot gas defrost applications to allow full open operation after defrost for fast pulldown
  • Capacities based on 60° saturated liquid, 0°F superheat at evaporator, 25°F superheated return gas, R404A, 0°F evaporator temperature, 2 psi ?P
  • Pressure range: 0-100 psi
(S)ORIT-12, -15 and -20 Features
- High side pilot for improved temperature control and low ΔP operation
- Adjustable
- Optional solenoid "stop" feature to close valve during defrost
- Normally open design allows system evacuation without manual operator
- These EPRs are pilot operated using "high side" pressure and require a pilot supply connection from the compressor discharge to operate. They are designed to be "normally open" providing an unparalleled ability to operate with virtually no suction line pressure drop. The pilot operated design does not require the "allowable evaporator pressure change" necessary with the direct acting models, and can be simply sized based on design evaporator temperature and available pressure drop across the valve at full load conditions.