Log in for pricing and inventory.

125R409A

125R409A
R409A refrigerant, HCFC, 125 lb. returnable cylinder
Specials Description :
R409A refrigerant, HCFC, 125 lb. returnable cylinder
LTL Only :
Yes
Hazmat :
Yes
Branch Pickup Only :
No
SKU :
125R409A
manufacturerName :
National Refrigerants, Inc.
Molecular Weight :
97.43
Pressure - Capacity Match :
10°F to 20°F Evap.
Note 1 :
returnable cylinder
manufacturerSKU :
125R409A
Refrigerant :
R409A
Container Size :
125 Lb Cylinder
Specials :
No
longDescription :

R-409A: A retrofit blend for R-12 refrigeration systems. The pressure and system capacity match R-12 when the blend is running in a 10°F to 20°F evaporator, and there is typically 13°F temperature glide in the evaporator. Applications: direct expansion refrigeration and air conditioning systems designed for R-12 or R-500; good success in any size system, minor adjustment of controls needed. Discharge pressure and temperature increases compared to R-12, which may be a problem in very hot ambient conditions. Capacity holds well into lower application temperatures (-30°F). R-409A mixes well with mineral oil down to 0°F. As a result it may not be necessary to change oil in systems which do not run colder than 0°F in the evaporator (below 0°F alkylbenzene should replace some mineral oil).

Weight :
176.0 lb
ASHRAE Standard 34 Safety Rating :
A1
LogoImage :
L/Logo_nri.jpg
Critical Pressure (psia) :
680.7
Sort :
3.0
Web Description :
R409A refrigerant, HCFC, 125 lb. returnable cylinder
Critical Density (Lb/Ft³) :
31.7
Vendor Name:
National Refrigerants, Inc.
URI Part Number:
125R409A
Vendor Part Number:
125R409A
Length (In.):
10.00
Width (In.):
10.00
Height (In.):
55.00
Composition (Weight %):
R-22/124/142b (60 / 25 / 15)
Critical Temperature ( Deg. F):
224.4
Shipping Weight (Lbs):
176.00
Weight (Lbs):
176.00

R-409A: A retrofit blend for R-12 refrigeration systems. The pressure and system capacity match R-12 when the blend is running in a 10°F to 20°F evaporator, and there is typically 13°F temperature glide in the evaporator. Applications: direct expansion refrigeration and air conditioning systems designed for R-12 or R-500; good success in any size system, minor adjustment of controls needed. Discharge pressure and temperature increases compared to R-12, which may be a problem in very hot ambient conditions. Capacity holds well into lower application temperatures (-30°F). R-409A mixes well with mineral oil down to 0°F. As a result it may not be necessary to change oil in systems which do not run colder than 0°F in the evaporator (below 0°F alkylbenzene should replace some mineral oil).

Tagalongs Documents