R502 refrigerant, CFC, 15 lb. cylinder
Refrigerant :
R502
Critical Pressure (psia) :
582.8
Weight :
20.0 lb
LTL Only :
Yes
longDescription :

AZEOTROPE: a mixture of two or more refrigerants in which the liquid and vapor have same composition at equilibrium. In addition, the resulting pressure of the mixture is either higher or lower than the pressure of any of the components. Azeotropes behave like pure component refrigerants because there is no change in boiling temperature or shift in composition during phase change, equipment operation, or leakage.



R-502: Before its phaseout in 1995, it was used in low temperature refrigeration (the evaporator pressure stays out of vacuum down to -40°F). R-502 offered lower discharge temperature and improved capacity compared to R-22. Commercial refrigeration systems could perform low temperature refrigeration in a single stage with relatively inexpensive compressors.
An EPA certification card is required to purchase CFC and HCFC refrigerants.

Container Size :
15 Lb Cylinder
Branch Pickup Only :
No
Web Description :
R502 refrigerant, CFC, 15 lb. cylinder
Vapor Density (bp, Lb./Ft³) :
0.388
manufacturerSKU :
INACTIVE
SKU :
15R502
Molecular Weight :
111.6
Specials :
No
manufacturerName :
National Refrigerants, Inc.
Hazmat :
yes
ASHRAE Standard 34 Safety Rating :
A1
LogoImage :
L/Logo_nri.jpg
Specials Description :
R502 refrigerant, CFC, 15 lb. cylinder
Sort :
2.0
Vendor Name:
National Refrigerants, Inc.
URI Part Number:
15R502
Vendor Part Number:
INACTIVE
Composition (Weight %):
R-22/R-115 (48.8/51.2)
Critical Temperature ( Deg. F):
177.3
Shipping Weight (Lbs):
20.00
Weight (Lbs):
20.00

AZEOTROPE: a mixture of two or more refrigerants in which the liquid and vapor have same composition at equilibrium. In addition, the resulting pressure of the mixture is either higher or lower than the pressure of any of the components. Azeotropes behave like pure component refrigerants because there is no change in boiling temperature or shift in composition during phase change, equipment operation, or leakage.



R-502: Before its phaseout in 1995, it was used in low temperature refrigeration (the evaporator pressure stays out of vacuum down to -40°F). R-502 offered lower discharge temperature and improved capacity compared to R-22. Commercial refrigeration systems could perform low temperature refrigeration in a single stage with relatively inexpensive compressors.
An EPA certification card is required to purchase CFC and HCFC refrigerants.