Log in for pricing and inventory.

5R508B

5R508B
R508B refrigerant, HFC, 5 lb. cylinder
Regional Item :
001,002,003,004,005,006,007,008,010,011,012,014,015,016,017,018,019,020,021,022,023,025,026,027,028,030,031,032,033,034,035,036,037,038,039,040,041,042,044,045,046,048,049,050,051,052,053,054,055,056,057,058,059,061,062,063,064,065,066,067,068,069,071,072,073,074,075,076,077,078,079,080,081,082,083,084,086,087,088,089,090,091,092,093,094,401,402,404,406,407,408,410,411,412,413,414,416,417,419,420,421,423,424,426,427,428,429,430,431,432,433,434,435,436,439,440,441,442,444,446,447,448,449,450,451,452,453,454,455,456,457,458,459,460,461,462,463,464,466,468,469,471,472,473,474,475,476,477,478,479,480,481,482,484,485,486,487,488,489,490,491,492,493,494,495,497,501,502,503,504,506,507,508,509,510,511,512,513,514,515,516,517,518,520,521,524,525,526,528,529,530,531,534,535,536,538,539,541,544,545,546,547,548,549,550,551,553,554,559,561,563,564,565,568,569,570,571,573,0A1,0A2,0A3,0A4,0A5,0A6,0A7,0A8,0A9,0B0,0B2,0B3,0B4,0B5,0B6,0B7,0B8,0C1,0C2,0C3,0D3,0E1,0E2,0E4,0E7,0E8,0F1,0F2,0F7,0F8,0F9,0G1,0G2,0G3,0G4,0G5,0G6,0H3,0H4,0H5,0H6,0H8,0I3,0I7,0J3,0J4,0J5,0J6,0J7,0P4,0P5,0P6,0P7,0P8,0P9,0R1,0R2,0R3,0R4,0R6,0R7,0R8,0R9,0S1,0S2,0S3,0S4,0S5,0S7,0T1,0T2,0T3,0T4,0T5,0T6,0T7,0T8,0T9,0U1,0U2,0V0,0V7,0V8,0W0,0W1,0W2,0W3,0W4,0W6,0W8,0W9,0X0,0X1,0X2,0X3,0X4,0X5,0X6,0X7,0X9,0Y1,0Y2,0Y3,0Y4,0Y5,0Y6,0Y7,0Y8,0Y9,0Z1,0Z2,0Z3,0Z4,0Z5,0Z6,0Z7,0Z8,095,096,0F7,0V7,575,576,577
Specials Description :
R508B refrigerant, HFC, 5 lb. cylinder
manufacturerName :
National Refrigerants, Inc.
Hazmat :
Yes
Branch Pickup Only :
No
Critical Pressure (psia) :
556.1
Refrigerant :
R508B
Web Description :
R508B refrigerant, HFC, 5 lb. cylinder
longDescription :

R-508B:
Used in very-low-temperature refrigeration systems, typically the low stage of a multi-stage system. R-508B has properties similar to R-503 and can be used to replace either R-13 or R-503 in an existing system. The discharge temperature does not increase significantly compared to R-23. POE lubricants should be used, and it may still be necessary to charge hydrocarbon oil additives to ensure proper oil return. Check with OEM for specific oil and charging recommendations.

Container Size :
5 Lb Cylinder
Specials :
No
SKU :
5R508B
Sort :
1.0
ASHRAE Standard 34 Safety Rating :
A1
LogoImage :
L/Logo_nri.jpg
Molecular Weight :
95.4
Weight :
14.0 lb
Liquid Density (20 F, Lb/Ft³) :
65.63
Vendor Name:
National Refrigerants, Inc.
Critical Density (Lb/Ft³) :
35.6
URI Part Number:
5R508B
Composition (Weight %):
R-23/116 (46 / 54)
Critical Temperature ( Deg. F):
53.7
Shipping Weight (Lbs):
14.00
RoHs 3:
Yes
Weight (Lbs):
14.00

R-508B:
Used in very-low-temperature refrigeration systems, typically the low stage of a multi-stage system. R-508B has properties similar to R-503 and can be used to replace either R-13 or R-503 in an existing system. The discharge temperature does not increase significantly compared to R-23. POE lubricants should be used, and it may still be necessary to charge hydrocarbon oil additives to ensure proper oil return. Check with OEM for specific oil and charging recommendations.

Documents