LDV2600M6D

LDV2600M6D
Call To Order
Condensing unit, air cooled, semi-hermetic compressor, medium/high temp, R404A, R507, 25+ HP, 460/3/60, w/ receiver
Engineered Items :
Yes
LTL Only :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Oil_short :
POE
Specials Description :
Condensing unit, air cooled, semi-hermetic compressor, medium/high temp, R404A, R507, 25+ HP, 460/3/60
Horsepower :
25
Receiver Capacity 90 % Full (Lbs.) :
123
SKU :
LDV2600M6D
Oil :
Polyol Ester
Web Search :
Volt
Application :
Medium Temp, High Temp
Specials :
No
Compressor New :
4DH3R22METSK
longDescription :

The LV outdoor Discus condensing unit features a new leak resistant design which includes:

  • The patented fully floating tube condenser coil. Refrigerant carrying copper tubes do not contact any meta support sheets; instead, the coil is constructed with expanded anchor tubes which support the coil construction and do not carry refrigerant. The coil design eliminates one of the major causes of leaks in refrigeration systems.
  • Limited five year warranty against condenser tube sheet and center support leaks
  • Prebent copper tubes minimize welded joints on internal piping
  • All sweat type connections, no flare joints to leak
  • Fixed high pressure switch eliminates capillary tubes

Standard Features

  • High efficiency Copeland Discus compressors with POE oil
  • Thermally protected permanently lubricated ball bearing condenser fan motor(s)
  • Electrical controls including compressor contactor and optional defrost control are located in easily accessible control box with a hinged cover
  • Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves
  • Cabinet is constructed from prepainted galvanized steel
  • Convenient access panels for easy servicing to internal components
  • Suction and discharge vibration eliminators
  • Separate subcooling circuit in condenser for added capacity and vapor free liquid
  • Liquid line filter drier and sight glass
  • Pressure relief valve on receiver
  • Crankcase heater
Vendor Name:
Larkin
Weight :
2,070.0 lb
Compressor :
4DH3A250ETSK
Sort :
8.0
Voltage :
460/3
Web Description :
Condensing unit, air cooled, semi-hermetic compressor, medium/high temp, R404A, R507, 25+ HP, 460/3/60, w/ receiver
Refrigerant :
R404A, R507
Connection Type :
ODS
manufacturerSKU :
LDV2600M6D
manufacturerName :
Larkin
URI Part Number:
LDV2600M6D
Vendor Part Number:
LDV2600M6D
Length (In.):
170.7
Width (In.):
44 1/2
Height (In.):
55 1/2
Connection Liquid (In.):
1 1/8
Connection Suction (In.):
2 1/8
MCA (Amps):
53.1
Receiver Included:
Yes
Shipping Weight (Lbs):
2070.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
2070.00

The LV outdoor Discus condensing unit features a new leak resistant design which includes:

  • The patented fully floating tube condenser coil. Refrigerant carrying copper tubes do not contact any meta support sheets; instead, the coil is constructed with expanded anchor tubes which support the coil construction and do not carry refrigerant. The coil design eliminates one of the major causes of leaks in refrigeration systems.
  • Limited five year warranty against condenser tube sheet and center support leaks
  • Prebent copper tubes minimize welded joints on internal piping
  • All sweat type connections, no flare joints to leak
  • Fixed high pressure switch eliminates capillary tubes

Standard Features

  • High efficiency Copeland Discus compressors with POE oil
  • Thermally protected permanently lubricated ball bearing condenser fan motor(s)
  • Electrical controls including compressor contactor and optional defrost control are located in easily accessible control box with a hinged cover
  • Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves
  • Cabinet is constructed from prepainted galvanized steel
  • Convenient access panels for easy servicing to internal components
  • Suction and discharge vibration eliminators
  • Separate subcooling circuit in condenser for added capacity and vapor free liquid
  • Liquid line filter drier and sight glass
  • Pressure relief valve on receiver
  • Crankcase heater