Log in for pricing and inventory.

LCH4105AB

LCH4105AB
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 10200 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 61-1/2" L
Specials Description :
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 10200 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 61 1/2" L
Voltage :
115/1
CFM :
1954
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
Engineered Items :
Yes
LTL Only :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Sort :
9.0
Fins/Inch :
4
Web Search :
evaporator walkin walk in
SKU :
LCH4105AB
Application :
Low Temp
manufacturerSKU :
LCH4105AB
Web Description :
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 10200 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 61-1/2" L
manufacturerName :
Larkin
Specials :
No
Vendor Name:
Larkin
Weight :
80.0 lb
Heater Amps :
7.8
Heater Watts :
900
Number of Motors :
3
Connection Type :
ODS
URI Part Number:
LCH4105AB
Vendor Part Number:
LCH4105AB
Length (In.):
61.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
7/8
Connection Suction (In.):
7/8
Shipping Weight (Lbs):
80.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
80.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD