Log in for pricing and inventory.

TPLP644MES2ER9ESPK

TPLP644MES2ER9ESPK
ESP+ A2L Low Profile Electric Defrost Pre-Assembled Evaporator Medium Temp 6 - FPI 44000 BTUH 208-230V 4080 CFM 6 Fans KIT READY
Sort :
16.0
Weight :
207.0 lb
LTL Only :
Yes
LogoImage :
L/Logo_TRENTON.jpg
Voltage :
208-230
Branch Pickup Only :
No
SKU :
TPLP644MES2ER9ESPK
Vendor Name:
Trenton Refrigeration Products
Capacity (BTUH) :
44000
Number of Motors :
6
Web Description :
ESP+ A2L Low Profile Electric Defrost Pre-Assembled Evaporator Medium Temp 6 - FPI 44000 BTUH 208-230V 4080 CFM 6 Fans KIT READY
Number of Fans :
6
Fins/Inch :
6
longDescription :
  • R454A/R454C/R455A
  • EC motors with patented SmartSpeed® Technologyigh efficiency and high strength fan guard
  • Fronnt access
  • Internally enhanced tubing
  • Convenient mounting brackets
  • Ample electrical and header compartments
  • Positive slope, hinged drain pan
  • Centrally located, universal drain connection
  • Large 3/4" ID (3/4" MPT) drain hole
  • Schrader valve on suction header, located outside of cabinet
  • All A2L units will include a Leak detection system with shipped loose SSOV (Safety Shut Off Valve) and CSOV (Check Shut Off Valve)
Application :
Medium Temp 6 - FPI
manufacturerName :
Trenton Refrigeration Products
Motor FLA :
3.6
Specials :
No
Motor Type :
EC Motor - SmartSpeed
Phase :
1
Refrigerant :
R454A, R454C, R455A
CFM :
4080
manufacturerSKU :
TPLP644MES2ER9ESPK
Hertz :
60
URI Part Number:
TPLP644MES2ER9ESPK
Vendor Part Number:
TPLP644MES2ER9ESPK
Length (In.):
13.44
Width (In.):
110.25
Height (In.):
15.88
Connection Liquid (In.):
1/2
Connection Size Inlet (In.):
1/2
Connection Suction (In.):
1 3/8
MCA (Amps):
3.8
Shipping Weight (Lbs):
207.00
Prop65:
WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
207.00
  • R454A/R454C/R455A
  • EC motors with patented SmartSpeed® Technologyigh efficiency and high strength fan guard
  • Fronnt access
  • Internally enhanced tubing
  • Convenient mounting brackets
  • Ample electrical and header compartments
  • Positive slope, hinged drain pan
  • Centrally located, universal drain connection
  • Large 3/4" ID (3/4" MPT) drain hole
  • Schrader valve on suction header, located outside of cabinet
  • All A2L units will include a Leak detection system with shipped loose SSOV (Safety Shut Off Valve) and CSOV (Check Shut Off Valve)