Log in for pricing and inventory.

S350AA1

S350AA1
System 350™, temperature stage adder module, reverse or direct acting, 1 to 30°F offset and differential
manufacturerName :
Johnson Controls
Specials Description :
System 350™, temperature stage adder module, reverse or direct acting, 1 to 30°F offset and differential
Branch Pickup Only :
No
Specials :
No
Description :
Temperature Stage Module
Sort :
1.0
Weight :
0.2 lb
longDescription :

S350A,C stage modules can be used with respective temperature (A350) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (1 to 30°F, 0.5 to 17°C), and offset (1 to 30°F, 0.5 to 17°C).
The S351 stage module can be used with respective humidity (W351) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (2 to 10% RH), and offset (2 to 30% RH).
S352 stage modules can be used with respective pressure (P352) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (2 to 50 psi), and offset (2 to 50 psi).
All stage modules have an SPDT relay output with LED indication.

LogoImage :
L/Logo_JohnsonControls.jpg
Web Description :
System 350™, temperature stage adder module, reverse or direct acting, 1 to 30°F offset and differential
Vendor Name:
Johnson Controls
manufacturerSKU :
S350AA-1C
SKU :
S350AA1
Web Search :
system 350
Contact Rating (Amps) :
4.9 F.L. Amps 240Vac
URI Part Number:
S350AA1
Vendor Part Number:
S350AA-1C
Length (In.):
5.60
Width (In.):
4.20
Height (In.):
3.50
Country of Origin:
MX
Shipping Weight (Lbs):
0.20
Prop65:
WARNING: This product contains chemicals known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
0.55

S350A,C stage modules can be used with respective temperature (A350) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (1 to 30°F, 0.5 to 17°C), and offset (1 to 30°F, 0.5 to 17°C).
The S351 stage module can be used with respective humidity (W351) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (2 to 10% RH), and offset (2 to 30% RH).
S352 stage modules can be used with respective pressure (P352) controls. The stage modules have three adjustments—reverse or direct-acting operation, differential (2 to 50 psi), and offset (2 to 50 psi).
All stage modules have an SPDT relay output with LED indication.

Documents