Log in for pricing and inventory.

RGS101LEAA0AAA

RGS101LEAA0AAA
Call To Order
Package A/C unit, electric cool, gas heat, 11 EER, R410A, 97,000 cooling BTUH, 224,000 heating input BTUH, 460/3/60
Engineered Items :
Yes
LTL Only :
Yes
Specials Description :
Package A/C unit, electric cool, gas heat, 11 EER, R410A, 97,000 cooling BTUH, 224,000 heating input BTUH, 460/3/60
Branch Pickup Only :
No
Sort :
12.0
Heating Efficiency DOE (AFUE) Standard :
80.0
LogoImage :
L/Logo_ArcoAire.jpg
manufacturerName :
Arcoaire
Maximum Fuse / Breaker Size (Amps) :
30
Web Description :
Package A/C unit, electric cool, gas heat, 11 EER, R410A, 97,000 cooling BTUH, 224,000 heating input BTUH, 460/3/60
Vendor Name:
Arcoaire
Efficiency AFUE :
80.0
SKU :
RGS101LEAA0AAA
Web Search :
Volt
Cooling Capacity (BTUH) :
97000
Weight :
910.0 lb
Heating Input (BTUH) Stage 1 :
125000
Specials :
No
Refrigerant :
R410A
Heating Input (BTUH) :
224000
Nominal Tons :
8 1/2
Voltage :
460/3
longDescription :
  • One piece, high efficiency gas heating, electric cooling with a low profile, prewired, tested, and charged
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Pre painted exterior panels and primer coated interior panels tested to 500 hours salt spray protection
  • Fully insulated cabinet
  • All units are convertible from downflow to horizontal airflow; no special adapter curbs are necessary
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving fan motor delay
  • High efficiency gas heat with induced draft flue exhaust design
  • All units have high and low pressure switches
  • Two inch disposable fiberglass type return air filters in dedicated rack with tool-less filter access door
  • Refrigerant circuits contain a liquid line filter drier to trap dirt and moisture
  • Exclusive non corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design
  • Belt drive evaporator fan motor and pulley combinations available to meet most applications
  • Access panels with easy grip handles provide quick and easy access to the blower and blower motor, control box, and compressors.
  • No strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal.
  • Newly designed terminal board facilitates simple safety circuit troubleshooting and simplified control box arrangement
  • Redundant gas valve, up to two stages of heating
  • Capable of thru-the-base or thru-the curb gas line routing
  • Outdoor temperature cooling operation range up to 115°F (46°C) and down to 30°F (-1°C ) [25°F for 6 to 12 1/2 ton units] using accessory winter start kit
  • Fixed orifice metering devices on all models to precisely control refrigerant flow
  • Large, laminated control wiring and power wiring drawings are affixed to unit to make troubleshooting easy
  • Single point gas and electrical connections


  • Single stage cooling capacity control
  • Single scroll compressor with internal line break overload protection
  • Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes
Heating Capacity (BTUH) :
148000
Drive :
Standard
URI Part Number:
RGS101LEAA0AAA
Length (In.):
88 1/8
Width (In.):
59 1/2
Height (In.):
49 3/8
MCA (Amps):
24.4
Shipping Weight (Lbs):
910.00
Weight (Lbs):
910.00
  • One piece, high efficiency gas heating, electric cooling with a low profile, prewired, tested, and charged
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Pre painted exterior panels and primer coated interior panels tested to 500 hours salt spray protection
  • Fully insulated cabinet
  • All units are convertible from downflow to horizontal airflow; no special adapter curbs are necessary
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving fan motor delay
  • High efficiency gas heat with induced draft flue exhaust design
  • All units have high and low pressure switches
  • Two inch disposable fiberglass type return air filters in dedicated rack with tool-less filter access door
  • Refrigerant circuits contain a liquid line filter drier to trap dirt and moisture
  • Exclusive non corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design
  • Belt drive evaporator fan motor and pulley combinations available to meet most applications
  • Access panels with easy grip handles provide quick and easy access to the blower and blower motor, control box, and compressors.
  • No strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal.
  • Newly designed terminal board facilitates simple safety circuit troubleshooting and simplified control box arrangement
  • Redundant gas valve, up to two stages of heating
  • Capable of thru-the-base or thru-the curb gas line routing
  • Outdoor temperature cooling operation range up to 115°F (46°C) and down to 30°F (-1°C ) [25°F for 6 to 12 1/2 ton units] using accessory winter start kit
  • Fixed orifice metering devices on all models to precisely control refrigerant flow
  • Large, laminated control wiring and power wiring drawings are affixed to unit to make troubleshooting easy
  • Single point gas and electrical connections


  • Single stage cooling capacity control
  • Single scroll compressor with internal line break overload protection
  • Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes
Documents