Catalog pricing shown. Please Sign In to see your pricing.

TZCAC090CLBA

TZCAC090CLBA
Package A/C unit, electric cool, 11 EER, R410A, 90,000 cooling BTUH, 208-230/3/60
Vendor Name:
Thermal Zone
URI Part Number:
TZCAC090CLBA
Vendor Part Number:
TZCAC090CLBA
Length (In.):
93 11/16
Width (In.):
58 3/4
Height (In.):
44
Shipping Weight (Lbs.):
1054
CFM:
3000
Cooling Capacity (BTUH):
90000
Cooling Efficiency (EER):
11.2
Maximum Fuse / Breaker Size (Amps):
50
MCA (Amps):
43
Motor Horsepower:
2
Nominal Tons:
7 1/2
Nominal Tons_Sort:
7.5
Refrigerant:
R410A
Sound Rating Decibels:
88
Voltage:
208-240/3
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
  • R-410A HFC refrigerant.
  • Complete factory charged, wired and run tested.
  • Scroll compressors with internal line break overload and high pressure protection.
  • Convertible airflow.
  • High pressure and low pressure/loss of charge protection standard on all models.
  • Solid core liquid line filter drier on each circuit.
  • Single slab, single pass designed evaporator and condenser(B072 and larger) coil facilitates easy cleaning for maintained high efficiencies.
  • Cooling operation up to 125°F ambient.
  • Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized.
  • Forkable base rails for easy handling and lifting.
  • Single point electrical connections.
  • Permanently lubricated evaporator, condenser and gas heat inducer motors.
  • Condenser motors are internally protected, totally enclosed with shaft down design.
  • 1 inch filter standard with slide out design.
  • Colored and labeled wiring.
  • Copper tube/aluminum fin coils.


  • Single stage compressor on B072, B085 models; two stage compressor on B090-B150 models
  • TXV refrigerant metering system on each circuit. (except B072, B085)
  • Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from air stream
  • Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers
  • Slide out indoor fan assembly for added service convenience
  • One piece top cover and one piece base pan with drawn
    supply and return opening for superior water management.
  • Internally sloped slide out condensate pan conforms to ASHRAE 62 standards
  • High performance belt drive motor with variable pitch pulleys and quick adjust belt system
  • 2 inch filter standard with slide out design
  • 24 volt control system with resettable circuit breakers
  • "B" suffix models use microchannel condenser coil technology