Log in for pricing and inventory.

5R503

5R503
R503 refrigerant, CFC, 5 lb. cylinder
Critical Density (Lb/Ft³) :
34.4
Hazmat :
Yes
Branch Pickup Only :
No
manufacturerName :
National Refrigerants, Inc.
Regional Item :
001,002,003,004,005,006,007,008,010,011,012,014,015,016,017,018,019,020,021,022,023,025,026,027,028,030,031,032,033,034,035,036,037,038,039,040,041,042,044,045,046,048,049,050,051,052,053,054,055,056,057,058,059,061,062,063,064,065,066,067,068,069,071,072,073,074,075,076,077,078,079,080,081,082,083,084,086,087,088,089,091,092,093,094,095,096,401,402,404,406,407,408,409,410,411,412,413,414,416,417,419,420,421,423,424,426,427,428,429,430,431,432,433,434,435,436,439,440,441,442,444,446,447,448,449,450,451,452,453,454,455,456,457,458,459,460,461,462,463,464,466,467,468,469,471,472,473,474,475,476,477,478,479,480,481,482,484,485,486,487,488,489,490,491,492,493,494,495,497,501,502,503,504,506,507,508,509,510,511,512,513,514,515,516,517,518,520,521,524,525,526,528,529,530,531,534,535,536,538,539,541,544,545,546,547,548,549,550,551,553,554,559,561,563,564,565,568,569,570,571,573,0A1,0A2,0A3,0A4,0A5,0A6,0A7,0A8,0A9,0B0,0B2,0B3,0B4,0B5,0B6,0B7,0B8,0B9,0C0,0C1,0C2,0C3,0C4,0C5,0C6,0C7,0C8,0C9,0D1,0D2,0D3,0D4,0D5,0D6,0D7,0D8,0D9,0E0,0E1,0E2,0E3,0E4,0E5,0E6,0E7,0E8,0F1,0F2,0F7,0F8,0F9,0G1,0G2,0G3,0G4,0G5,0G6,0H3,0H4,0H5,0H6,0H8,0I3,0I7,0J3,0J4,0J5,0J6,0J7,0P1,0P2,0P4,0P5,0P6,0P7,0P8,0P9,0R1,0R2,0R3,0R4,0R6,0R7,0R8,0R9,0S1,0S2,0S3,0S4,0S5,0S6,0S7,0T1,0T2,0T3,0T4,0T5,0T6,0T7,0T8,0T9,0U1,0U2,0V0,0V7,0V8,0W0,0W1,0W2,0W3,0W4,0W6,0W8,0W9,0X0,0X1,0X2,0X3,0X4,0X5,0X6,0X7,0X9,0Y1,0Y2,0Y3,0Y4,0Y5,0Y6,0Y7,0Y8,0Y9,0Z1,0Z2,0Z3,0Z4,0Z5,0Z6,0Z7,0Z8
Web Description :
R503 refrigerant, CFC, 5 lb. cylinder
Liquid Density (20 F, Lb/Ft³) :
66.3
Specials Description :
R503 refrigerant, CFC, 5 lb. cylinder
Container Size :
5 Lb Cylinder
longDescription :

R-503:
Very low temperature refrigeration systems typically operate in two or more stages (cascade type systems). It would be nearly impossible to achieve low temperatures in a single stage with an inexpensive compressor. Older cascade systems had a low temperature stage which used a lower boiling point gas, such as R-13 or R-503, and a high stage which traditionally used R-12, R-22, or R-502. Hydrocarbons are often added to very low temperature systems to make sure the oil stays fluid and returns from the very cold evaporator.
R-503 can be replaced by R-508B.

Molecular Weight :
82.25
Refrigerant :
R503
Specials :
No
ASHRAE Standard 34 Safety Rating :
A1
LogoImage :
L/Logo_nri.jpg
SKU :
5R503
Critical Pressure (psia) :
618.6
Weight :
14.0 lb
Sort :
2.0
Vendor Name:
National Refrigerants, Inc.
URI Part Number:
5R503
Composition (Weight %):
R-23/R-13 (40.1/59.9)
Critical Temperature ( Deg. F):
65.2
Shipping Weight (Lbs):
14.00
Weight (Lbs):
14.00

R-503:
Very low temperature refrigeration systems typically operate in two or more stages (cascade type systems). It would be nearly impossible to achieve low temperatures in a single stage with an inexpensive compressor. Older cascade systems had a low temperature stage which used a lower boiling point gas, such as R-13 or R-503, and a high stage which traditionally used R-12, R-22, or R-502. Hydrocarbons are often added to very low temperature systems to make sure the oil stays fluid and returns from the very cold evaporator.
R-503 can be replaced by R-508B.