Log in for pricing and inventory.

LCH4174AB

LCH4174AB
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 17000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 93-1/2" L
Voltage :
115/1
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
Engineered Items :
Yes
LTL Only :
Yes
Number of Motors :
5
Sort :
13.0
manufacturerName :
Larkin
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Fins/Inch :
4
Web Description :
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 17000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 93-1/2" L
Web Search :
evaporator walkin walk in
CFM :
3107
manufacturerSKU :
LCH4174AB
Specials :
No
Vendor Name:
Larkin
Heater Watts :
1500
Weight :
204.0 lb
Heater Amps :
13
Connection Type :
ODS
Specials Description :
Unit cooler, walk-in, 4 FPI, hot gas defrost, low profile, 17000 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 93 1/2" L
SKU :
LCH4174AB
URI Part Number:
LCH4174AB
Vendor Part Number:
LCH4174AB
Length (In.):
93.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
7/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
204.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
204.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
Substitutes Documents