Log in for pricing and inventory.

LCH6140BB

LCH6140BB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 14000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 61-1/2" L
Engineered Items :
Yes
LTL Only :
Yes
manufacturerName :
Larkin
LogoImage :
L/Logo_LARKIN.jpg
Branch Pickup Only :
No
Voltage :
208-240/1
Web Search :
evaporator walkin walk in
Fins/Inch :
6
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 14000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 61-1/2" L
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Sort :
14.0
CFM :
1950
Specials :
No
Heater Amps :
3.9
Vendor Name:
Larkin
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 14000 BTUH -20°F, 208-230/1/60, 14 3/4" H x 14 15/16" W x 61 1/2" L
SKU :
LCH6140BB
Heater Watts :
900
Weight :
84.0 lb
Number of Motors :
3
manufacturerSKU :
LCH6140BB
Connection Type :
ODS
URI Part Number:
LCH6140BB
Vendor Part Number:
LCH6140BB
Length (In.):
61.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
7/8
Connection Suction (In.):
7/8
Shipping Weight (Lbs):
84.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
84.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available