Log in for pricing and inventory.

LCH6160BB

LCH6160BB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 16000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 77-1/2" L
Sort :
16.0
Engineered Items :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Voltage :
208-240/1
SKU :
LCH6160BB
Number of Motors :
4
Web Search :
evaporator walkin walk in
Fins/Inch :
6
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Weight :
104.0 lb
Heater Amps :
5.2
Specials :
No
manufacturerSKU :
LCH6160BB
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 16000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 77-1/2" L
Vendor Name:
Larkin
Heater Watts :
1200
manufacturerName :
Larkin
CFM :
2600
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 16000 BTUH -20°F, 208-230/1/60, 14 3/4" H x 14 15/16" W x 77 1/2" L
Connection Type :
ODS
URI Part Number:
LCH6160BB
Vendor Part Number:
LCH6160BB
Length (In.):
77.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
7/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
104.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
104.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Substitutes Documents