Log in for pricing and inventory.

LCH6180AB

LCH6180AB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 18000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 77-1/2" L
Sort :
17.0
Voltage :
115/1
Engineered Items :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 18000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 77-1/2" L
Number of Motors :
4
Web Search :
evaporator walkin walk in
Fins/Inch :
6
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
SKU :
LCH6180AB
Heater Amps :
10.4
manufacturerName :
Larkin
manufacturerSKU :
LCH6180AB
Specials :
No
Vendor Name:
Larkin
Heater Watts :
1200
Weight :
108.0 lb
CFM :
2600
Connection Type :
ODS
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 18000 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 77 1/2" L
URI Part Number:
LCH6180AB
Vendor Part Number:
LCH6180AB
Length (In.):
77.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
1 1/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
108.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
108.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available