Log in for pricing and inventory.

LCH6240BB

LCH6240BB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 24000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 109-1/2" L
Weight :
234.0 lb
Engineered Items :
Yes
LTL Only :
Yes
Sort :
22.0
LogoImage :
L/Logo_LARKIN.jpg
Branch Pickup Only :
No
Voltage :
208-240/1
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 24000 BTUH -20°F, 208-230/1/60, 14 3/4" H x 14 15/16" W x 109 1/2" L
Number of Motors :
6
Web Search :
evaporator walkin walk in
Fins/Inch :
6
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
SKU :
LCH6240BB
CFM :
3900
Heater Watts :
1800
Specials :
No
Vendor Name:
Larkin
Heater Amps :
7.8
manufacturerSKU :
LCH6240BB
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 24000 BTUH -20°F, 208-230/1/60 volt, 14-3/4" H x 14-15/16" W x 109-1/2" L
Connection Type :
ODS
manufacturerName :
Larkin
URI Part Number:
LCH6240BB
Vendor Part Number:
LCH6240BB
Length (In.):
109.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
1 1/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
234.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
234.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available