Log in for pricing and inventory.

LCH6270AB

LCH6270AB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 27000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 109-1/2" L
Weight :
234.0 lb
Voltage :
115/1
Engineered Items :
Yes
LTL Only :
Yes
LogoImage :
L/Logo_LARKIN.jpg
Branch Pickup Only :
No
Number of Motors :
6
Web Search :
evaporator walkin walk in
Fins/Inch :
6
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
manufacturerName :
Larkin
SKU :
LCH6270AB
CFM :
3900
Heater Watts :
1800
Specials :
No
Vendor Name:
Larkin
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 27000 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 109-1/2" L
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 27000 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 109 1/2" L
manufacturerSKU :
LCH6270AB
Heater Amps :
15.7
Sort :
23.0
Connection Type :
ODS
URI Part Number:
LCH6270AB
Vendor Part Number:
LCH6270AB
Length (In.):
109.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
1 1/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
234.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
234.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Substitutes Documents