Log in for pricing and inventory.

LCH665AB

LCH665AB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 6500 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 45-1/2" L
Voltage :
115/1
Engineered Items :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 6500 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 45-1/2" L
Heater Watts :
600
Weight :
58.0 lb
SKU :
LCH665AB
Web Search :
evaporator walkin walk in
Fins/Inch :
6
CFM :
1400
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 6500 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 45 1/2" L
Heater Amps :
5.2
manufacturerName :
Larkin
Specials :
No
Vendor Name:
Larkin
Number of Motors :
2
Connection Type :
ODS
manufacturerSKU :
LCH665AB
Sort :
5.0
URI Part Number:
LCH665AB
Vendor Part Number:
LCH665AB
Length (In.):
45.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
5/8
Connection Suction (In.):
5/8
Shipping Weight (Lbs):
58.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
58.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Documents