Log in for pricing and inventory.

MOH020X63CFM

MOH020X63CFM
Condensing unit, air cooled, hermetic compressor, outdoor, medium/low temp, R404A, R507, 2 HP, 208-230/3/60, w/ receiver
Engineered Items :
Yes
LTL Only :
Yes
Web Description :
Condensing unit, air cooled, hermetic compressor, outdoor, medium/low temp, R404A, R507, 2 HP, 208-230/3/60, w/ receiver
Compressor :
CS12K6ETF5
Branch Pickup Only :
No
Oil_short :
POE
Sort :
9.0
Refrigerant :
R404A
manufacturerSKU :
MOH020X63CFM
SKU :
MOH020X63CFM
Specials Description :
Condensing unit, air cooled, hermetic compressor, outdoor, medium/low temp, R404A, R507, 2 HP, 208-230/3/60
longDescription :

Units from 1/2 to 6 HP now feature HyperCore™ microchannel coil technology

  • Rigid, damage resistant structure; increases coil life
  • Monometal (aluminum) construction avoids galvanic corrosion and offers a significant weight advantage
  • Reduces required refrigerant charge
  • Reduces braze operations (1) vs RTPF (50 to 100) and thus the likelihood of leaks

Standard Features:

  • Motors rated for 50 and 60 cycle application
  • Fans specifically matched with motor and coil to attain maximum air movement and cooling
  • Prepainted G90 galvanized cabinets for superior strength and corrosion protection including hoods for outdoor units
  • Heavy duty steel raised base with 1 1/2" legs
  • A receiver with fusible plug, liquid shutoff valve and charging port is also standard.
  • Discharge service valves on all compressors
  • Large electrical panel for ease of access
  • Prefabricated wiring harnesses for tight connections and to simplify service
  • Encapsulated, auto-reset, high pressure controls to eliminate leaks
  • All units completely leak tested in a helium environment and run tested. Each unit will have a copy of the run data shipped inside the electrical panel.
  • Crankcase heater
  • Flooded head pressure control valve
  • Liquid line drier, sight glass
    Many optional features available


  • Suction service valves located outside the cabinet for quick installations.
  • Encapsulated auto reset low pressure control
  • Models 1 HP and smaller (RS compressor) not suitable for R507 applications
Vendor Name:
Heatcraft
Oil :
Polyol Ester
Web Search :
Volt
LogoImage :
L/Logo_Heatcraft.jpg
Horsepower :
2
Specials :
No
manufacturerName :
Heatcraft
Receiver Capacity 90 % Full (Lbs.) :
9
Weight :
203.0 lb
Voltage :
208-240/3
Regional Item :
085,409,0B9,0C0,0C4,0C5,0C6,0C7,0C8,0C9,0D0,0D1,0D2,0D4,0D5,0D6,0D7,0D8,0D9,0E0,0E3,0E5,0E6,0P1,0P2,0S6
Connection Type :
ODS
URI Part Number:
MOH020X63CFM
Vendor Part Number:
MOH020X63CFM
Length (In.):
28 1/4
Width (In.):
37 3/4
Height (In.):
17 1/4
Connection Liquid (In.):
3/8
Connection Suction (In.):
7/8
MCA (Amps):
15
Receiver Included:
Yes
Shipping Weight (Lbs):
203.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
203.00

Units from 1/2 to 6 HP now feature HyperCore™ microchannel coil technology

  • Rigid, damage resistant structure; increases coil life
  • Monometal (aluminum) construction avoids galvanic corrosion and offers a significant weight advantage
  • Reduces required refrigerant charge
  • Reduces braze operations (1) vs RTPF (50 to 100) and thus the likelihood of leaks

Standard Features:

  • Motors rated for 50 and 60 cycle application
  • Fans specifically matched with motor and coil to attain maximum air movement and cooling
  • Prepainted G90 galvanized cabinets for superior strength and corrosion protection including hoods for outdoor units
  • Heavy duty steel raised base with 1 1/2" legs
  • A receiver with fusible plug, liquid shutoff valve and charging port is also standard.
  • Discharge service valves on all compressors
  • Large electrical panel for ease of access
  • Prefabricated wiring harnesses for tight connections and to simplify service
  • Encapsulated, auto-reset, high pressure controls to eliminate leaks
  • All units completely leak tested in a helium environment and run tested. Each unit will have a copy of the run data shipped inside the electrical panel.
  • Crankcase heater
  • Flooded head pressure control valve
  • Liquid line drier, sight glass
    Many optional features available


  • Suction service valves located outside the cabinet for quick installations.
  • Encapsulated auto reset low pressure control
  • Models 1 HP and smaller (RS compressor) not suitable for R507 applications