Log in for pricing and inventory.

WK130AC

WK130AC
Unit cooler, walk-in, air defrost, low profile, low velocity, 13000 BTUH +25°F, 115/1/60 volt, 15-1/8" H x 26-5/8" W x 75-1/2" L
Please note an alternative model exists for this Part Number. Please see the Supersedes tab.
Weight :
234.0 lb
Voltage :
115/1
Engineered Items :
Yes
LTL Only :
Yes
Vendor Name:
Bohn
Branch Pickup Only :
No
longDescription :

Ideal for floral storage, fresh fruit and vegetables, dough retarding, fresh meat storage and preparations, and many other applications. The low air flow and quiet fans are classically suited for work room applications. The generous coil surface combined with close T.D. system balance provides high humidity characteristics to minimize product shrinkage and drying.

  • WK Capacity 10°F T.D. Suitable for applications +35°F to +55°F
  • WKE, WKG Capacity 10°F T.D. +25°F SST. Suitable for applications +24°F to +34°F
  • Glycol models: capacity rated at 35°F room temperature, indicated fluid GPM, fluid pressure difference is approximately 7.5 psi, assumes 35% propylene at +20°F, +20°F entering fluid temperature, indicated leaving fluid temperature rise
    Please contact Customer Service for glycol capacities at specifications other than above


  • Capacity @ 10°F T.D. Suitable for applications +35°F to +55°F
Web Search :
evaporator walkin walk in
SKU :
WK130AC
LogoImage :
L/Logo_BOHN.jpg
Specials Description :
Unit cooler, walk-in, air defrost, low profile, low velocity, 13000 BTUH +25°F, 115/1/60, 15 1/8" H x 26 5/8" W x 75 1/2" L
Specials :
No
manufacturerSKU :
WK130AC
manufacturerName :
Bohn
Number of Motors :
2
Web Description :
Unit cooler, walk-in, air defrost, low profile, low velocity, 13000 BTUH +25°F, 115/1/60 volt, 15-1/8" H x 26-5/8" W x 75-1/2" L
Sort :
7.0
Connection Type :
ODS
CFM :
1470
URI Part Number:
WK130AC
Vendor Part Number:
WK130AC
Length (In.):
75 1/2
Width (In.):
26 5/8
Height (In.):
15 1/8
Connection Size Inlet (In.):
1 1/8
Connection Suction (In.):
1 1/8
Shipping Weight (Lbs):
234.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
234.00

Ideal for floral storage, fresh fruit and vegetables, dough retarding, fresh meat storage and preparations, and many other applications. The low air flow and quiet fans are classically suited for work room applications. The generous coil surface combined with close T.D. system balance provides high humidity characteristics to minimize product shrinkage and drying.

  • WK Capacity 10°F T.D. Suitable for applications +35°F to +55°F
  • WKE, WKG Capacity 10°F T.D. +25°F SST. Suitable for applications +24°F to +34°F
  • Glycol models: capacity rated at 35°F room temperature, indicated fluid GPM, fluid pressure difference is approximately 7.5 psi, assumes 35% propylene at +20°F, +20°F entering fluid temperature, indicated leaving fluid temperature rise
    Please contact Customer Service for glycol capacities at specifications other than above


  • Capacity @ 10°F T.D. Suitable for applications +35°F to +55°F