Log in for pricing and inventory.

26EH5C2-R1021E

26EH5C2-R1021E
Solenoid valve, secondary coolant, normally closed, 1-5/8" ODS, 12.2 Cv
Engineered Items :
Yes
Branch Pickup Only :
No
Web Description :
Solenoid valve, secondary coolant, normally closed, 1-5/8" ODS, 12.2 Cv
LogoImage :
L/Logo_PARKER.jpg
manufacturerName :
Parker
Specials Description :
Solenoid valve, secondary coolant, normally closed, 1 5/8" ODS, 12.2 Cv
Weight :
5.3 lb
Flow (Cv) :
12.2
MOPD :
0 - 50
longDescription :

Parker Hannifin, a pioneer in supermarket refrigeration control, introduces a new line of solenoid valves to control secondary coolants. These fluids include propylene glycol, ethylene glycol, Pecasol 50, Dynalene HC-40, and others. Parker's valve is the only valve designed to meet the requirements of both medium and low temperature applications encountered in supermarket applications.
In a secondary coolant, or secondary loop system, a chilled solution, such as propylene glycol, is circulated throughout the system rather than liquid refrigerant. Secondary coolant systems are advantageous because they can eliminate liquid refrigerant and suction gas lines running through a store. This reduces installation costs and labor, and eliminates costly refrigerant leaks.
Also, PVC tubing can be used, rather than the heavier, more expensive copper tubing normally used in traditional systems. Again, this reduces installation costs and labor, and eliminates costly refrigerant leaks. Another benefit is more efficient defrost cycles with less potential product damage.
Coil not included; order separately.



A new line of solenoid valves to control secondary coolant. These fluids include propylene glycol, ethylene glycol, Pecasol 50, Dynalene HC-40 and others. Parker's valve is the only valve designed to meet the requirements of both medium and low temperature applications encountered in supermarket applications.
Specials :
No
Vendor Name:
Parker
SKU :
26EH5C2-R1021E
manufacturerSKU :
4140-00
Connection Type :
ODS
Use Coil Model :
CF5C, CF5E
Sort :
5.0
URI Part Number:
26EH5C2-R1021E
Vendor Part Number:
4140-00
Length (In.):
11.70
Width (In.):
6.70
Height (In.):
3.40
Connection Size (In.):
1 5/8
Overall Length (In.):
9.38
Shipping Weight (Lbs):
5.30
Prop65:
WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
10.00

Parker Hannifin, a pioneer in supermarket refrigeration control, introduces a new line of solenoid valves to control secondary coolants. These fluids include propylene glycol, ethylene glycol, Pecasol 50, Dynalene HC-40, and others. Parker's valve is the only valve designed to meet the requirements of both medium and low temperature applications encountered in supermarket applications.
In a secondary coolant, or secondary loop system, a chilled solution, such as propylene glycol, is circulated throughout the system rather than liquid refrigerant. Secondary coolant systems are advantageous because they can eliminate liquid refrigerant and suction gas lines running through a store. This reduces installation costs and labor, and eliminates costly refrigerant leaks.
Also, PVC tubing can be used, rather than the heavier, more expensive copper tubing normally used in traditional systems. Again, this reduces installation costs and labor, and eliminates costly refrigerant leaks. Another benefit is more efficient defrost cycles with less potential product damage.
Coil not included; order separately.



A new line of solenoid valves to control secondary coolant. These fluids include propylene glycol, ethylene glycol, Pecasol 50, Dynalene HC-40 and others. Parker's valve is the only valve designed to meet the requirements of both medium and low temperature applications encountered in supermarket applications.