Log in for pricing and inventory.

13R402B

13R402B
R402B refrigerant, HCFC, 13 lb. cylinder
Regional Item :
001,002,003,004,005,006,007,008,010,011,012,014,015,016,017,018,019,020,021,022,023,025,026,027,028,030,031,032,033,034,035,036,037,038,039,040,041,042,044,045,046,048,049,050,051,052,053,054,055,056,057,058,059,061,062,063,064,065,066,067,068,069,071,072,073,074,075,076,077,078,079,080,081,082,083,084,086,087,088,089,090,091,092,093,094,401,402,404,406,407,408,410,411,412,413,414,416,417,419,420,421,423,424,426,427,428,429,430,431,432,433,434,435,436,439,440,441,442,444,446,447,448,449,450,451,452,453,454,455,456,457,458,459,460,461,462,463,464,466,468,469,471,472,473,474,475,476,477,478,479,480,481,482,484,485,486,487,488,489,490,491,492,493,494,495,497,501,502,503,504,506,507,508,509,510,511,512,513,514,515,516,517,518,520,521,524,525,526,528,529,530,531,534,535,536,538,539,541,544,545,546,547,548,549,550,551,553,554,559,561,563,564,565,568,569,570,571,573,0A1,0A2,0A3,0A4,0A5,0A6,0A7,0A8,0A9,0B0,0B2,0B3,0B4,0B5,0B6,0B7,0B8,0C1,0C2,0C3,0D3,0E1,0E2,0E4,0E7,0E8,0F1,0F2,0F7,0F8,0F9,0G1,0G2,0G3,0G4,0G5,0G6,0H3,0H4,0H5,0H6,0H8,0I3,0I7,0J3,0J4,0J5,0J6,0J7,0P4,0P5,0P6,0P7,0P8,0P9,0R1,0R2,0R3,0R4,0R6,0R7,0R8,0R9,0S1,0S2,0S3,0S4,0S5,0S7,0T1,0T2,0T3,0T4,0T5,0T6,0T7,0T8,0T9,0U1,0U2,0V0,0V7,0V8,0W0,0W1,0W2,0W3,0W4,0W6,0W8,0W9,0X0,0X1,0X2,0X3,0X4,0X5,0X6,0X7,0X9,0Y1,0Y2,0Y3,0Y4,0Y5,0Y6,0Y7,0Y8,0Y9,0Z1,0Z2,0Z3,0Z4,0Z5,0Z6,0Z7,0Z8,095,096,0F7,0V7,575,576,577
Weight :
17.0 lb
Container Size :
13 Lb Cylinder
Specials Description :
R402B refrigerant, HCFC, 13 lb. cylinder
Refrigerant :
R402B
Molecular Weight :
94.7
Hazmat :
Yes
Branch Pickup Only :
No
manufacturerName :
National Refrigerants, Inc.
Specials :
No
Sort :
1.0
ASHRAE Standard 34 Safety Rating :
A1
LogoImage :
L/Logo_nri.jpg
Critical Density (Lb/Ft³) :
33.1
Web Description :
R402B refrigerant, HCFC, 13 lb. cylinder
SKU :
13R402B
longDescription :

R-402B: Similar components to R-402A but contains more R-22 and less R-125. This lowers the discharge pressure closer to R-502, however the discharge temperature increases compared to R-502. This is a benefit in ice machines, where the blend is primarily used, because it improves harvest times. Although propane was included to improve oil circulation it is still recommended that some mineral oil be removed and replaced with alkylbenzene or POE.

Critical Pressure (psia) :
645.0
Vendor Name:
National Refrigerants, Inc.
URI Part Number:
13R402B
Composition (Weight %):
R-125/290/22 (38 / 2 / 60)
Critical Temperature ( Deg. F):
180.7
Shipping Weight (Lbs):
17.00
Weight (Lbs):
17.00

R-402B: Similar components to R-402A but contains more R-22 and less R-125. This lowers the discharge pressure closer to R-502, however the discharge temperature increases compared to R-502. This is a benefit in ice machines, where the blend is primarily used, because it improves harvest times. Although propane was included to improve oil circulation it is still recommended that some mineral oil be removed and replaced with alkylbenzene or POE.