Log in for pricing and inventory.

LCH676AB

LCH676AB
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 7600 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 45-1/2" L
Voltage :
115/1
Engineered Items :
Yes
Branch Pickup Only :
No
LogoImage :
L/Logo_LARKIN.jpg
Specials Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 7600 BTUH -20°F, 115/1/60, 14 3/4" H x 14 15/16" W x 45 1/2" L
Heater Watts :
600
Web Description :
Unit cooler, walk-in, 6 FPI, hot gas defrost, low profile, 7600 BTUH -20°F, 115/1/60 volt, 14-3/4" H x 14-15/16" W x 45-1/2" L
Web Search :
evaporator walkin walk in
Weight :
64.0 lb
Fins/Inch :
6
manufacturerSKU :
LCH676AB
longDescription :

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
manufacturerName :
Larkin
Heater Amps :
5.2
Specials :
No
Vendor Name:
Larkin
Number of Motors :
2
Sort :
7.0
SKU :
LCH676AB
CFM :
1300
Connection Type :
ODS
URI Part Number:
LCH676AB
Vendor Part Number:
LCH676AB
Length (In.):
45.5
Width (In.):
15
Height (In.):
15
Connection Size Inlet (In.):
7/8
Connection Suction (In.):
5/8
Shipping Weight (Lbs):
64.00
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
Weight (Lbs):
64.00

New design allows easy front access to electrical and refrigeration components. More volume in electrical cavity for component installation. Heaters are attached to coil... no need to disconnect from electrical board to drop drain pan.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • BTU 10°F TD, -20°F SST


New design allows easy front access to electrical and refrigeration
components. More volume in electrical cavity for component installation.

  • For applications -20°F and above
  • Width: 15" (16 5/8" at refrigerant connections)
  • Height: 15" (16" at drain spud)
  • Capacity rated 10°F TD
  • Glycol models available
Documents